Client who is testing an iPRO RC for the first time and created a Linux ccTalk app for it.
Communication with the unit works, along with majority of the ccTalk functions, but somehow they can not get function ReadBufferedBillEvents to work, because the response is not valid (see the request/response below).
Even if they use simulator (v.4), there is no way to get the unit to show bill denomination and store it accordingly.
Test in their app and tested with simulator returns the same error.
### Log from APP ###
26.02.2023 22:30:22.827 INFO link_controller >> > ccTalk request: ReadBufferedBillEvents, address: 40, data: (empty)
26.02.2023 22:30:22.828 INFO serial_worker >> > Request: 2800319f5d
26.02.2023 22:30:22.899 INFO serial_worker >> < Full response: 2800319f5d010b2d000200000000000080
26.02.2023 22:30:22.899 INFO serial_worker >> < Response: 010b2d000200000000000080
26.02.2023 22:30:22.899 INFO message size: 12, data size: 11, command data: 8
26.02.2023 22:30:22.899 INFO ! Invalid ccTalk response #31 size; 12 bytes instead of 16.
### END ###
Answer:
connecting to a PC using our ccTalk simulator and JCM’s UAC. The GA0013 harness was designed specifically for this purpose