I regret to inform you that there is another display that developed a serious issue:
In this photo, the unit should display a blank, black background (other than the "TankAuto" shortcut and the Windows taskbar).
At first, restarting the unit solved the problem temporarily, but now the image retention / distortion is continuous.
The unit itself had been delivered in May 2024 and was installed in an OPT in December 2024. It was working fine until about 2 weeks ago.
S/N: VM43B1 V2ET02240306012
Can I ask for a booting method or advice before opening an RMA request?
Answer:
We suggest following the below steps before shipping back:
- Change a computer or signal source.
2. Start the OSD factory mode (R/G/B/black/white pattern) – connect power but not any signal cable. Push OSD button VOL+ (third button) then click POWER (first button) to enable the factory mode. Check if the stripes pattern still on the screen.
- Reconnect the tcon board as the below connectors in red rectangles (power must be off when reconnecting.)
- (When power on) slightly pet the black mylar area on the screen to check if the stripes changing. This is a risk method so you could choose not to do.